                                  Violation 0
********************************************************************************
title: WARNING: DRC doesn't catch everything
explanation: Detection of outright shorts, missing connections, etc.
is handled via rat's nest addition.  To catch these problems,
display the message log using Window->Message Log, then use
Connects->Optimize rats nest (O hotkey) and watch for messages.

location: (x, y) = (0, 0), angle = 0.000000
have_measured: true
measured value: 0
required value: 0
object count: 0
object IDs: 
object types: 

********************************************************************************
                                  Violation 1
********************************************************************************
title: Potential for broken trace
explanation: Insufficient overlap between objects can lead to broken tracks
due to registration errors with old wheel style photo-plotters.
location: (x, y) = (9741278, 8674100), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 137 118 
object types: 16384 4 

********************************************************************************
                                  Violation 2
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (10591423, 7226300), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 138 121 
object types: 16384 4 

********************************************************************************
                                  Violation 3
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (5562223, 15862300), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 145 88 
object types: 16384 4 

********************************************************************************
                                  Violation 4
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (4610478, 17310100), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 144 82 
object types: 16384 4 

********************************************************************************
                                  Violation 5
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (5536823, 18757900), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 143 76 
object types: 16384 4 

********************************************************************************
                                  Violation 6
********************************************************************************
title: Copper areas too close
explanation: Circuits that are too close may bridge during imaging, etching,
plating, or soldering processes resulting in a direct short.
location: (x, y) = (4635878, 20180300), angle = 0.000000
have_measured: false
measured value: 0
required value: 127000
object count: 2
object IDs: 142 67 
object types: 16384 4 